Düşünceleriniz Bizim İçin Önemli!
Lion 200 is a 3-phase charger with capacities up to 20 kW. The charger can be powered by all commonly existing mains voltages and many of the models are certified according to UL and CSA standards for use in the USA and Canada by Underwriters Laboratories.
The Lion charger from Micropower provides you with powerful and energy efficient battery charging. The modern state of the art MOSFET power conversion circuit efficiently and accurately converts AC power to the proper DC power levels required to charge different kinds Lion-Ion batteries. The chargers are preprogramed from our factory but can easily be reprogramed if working conditions (such as new kinds of Lion-Ion battery) are to change.
The Lion charger comes with real-time clock, radio transceiver and remote start in standard edition. On top of that there are additional accessories to add. Please see the accessories tab.
The Lion chargers are equipped with a I/O card for CAN-bus communication.
Statistics and information about deviations from the last 2000 charging cycles are stored in the Lion chargers memory. The information can be accessed either via the charger display or, using the Access Service Tool, on a laptop.
– Energy efficient MOSFET design.
– Possibility to add three charge block-out periods to avoid times of peak demand and optimize energy cost if time of day billing are in use.
– Lion adapts its power use according to available main fuse. This way the charger always gives maximum power possible.
– Wireless maximum power. This feature makes it possible to limit total power consumption for a group of chargers.
PROPERTIES |
|
IP ENCLOSURE | IP54 |
CERTIFICATE | |
REPORTING | IP54 |
APPLICATION | Standard |
Battery voltage | Current (A) | Number of phases | Primary voltage, min-max (v) | 8 hours cap.ah/5h | 10 hours cap.ah/5h | Cabinet size | Weight (kg) |
24 | 400 | 3-phase | 380 - 415 | A22 | 31 | ||
36 | 300 | 3-phase | 380 - 415 | A22 | 31 | ||
340 | 3-phase | 208 - 240 | A22 | 31 | |||
410 | 3-phase | 440 - 440 | A22 | 31 | |||
420 | 3-phase | 480 - 480 | A22 | 31 | |||
48 | 260 | 3-phase | 208 - 240 | A22 | 31 | ||
260 | 3-phase | 440 - 440 | A22 | 31 | |||
330 | 3-phase | 380 - 415 | A22 | 31 | |||
330 | 3-phase | 480 - 480 | A22 | 31 | |||
80 | 120 | 3-phase | 208 - 240 | A22 | 31 | ||
200 | 3-phase | 380 - 415 | A22 | 31 | |||
200 | 3-phase | 440 - 440 | A22 | 31 | |||
200 | 3-phase | 480 - 480 | A22 | 31 |
Our stands fit all Access, Lion and Sharp chargers. The stands are available in two models, one bench and one floor stand.
All our chargers will automatically start when the battery charger is connected to the battery. Likewise it will automatically stop when the charger is disconnected. This option eliminates the risk of sparks when disconnecting the charger.
The Access Service Tool allows you to wirelessly download the complete charging statistics from the last 2000 charging cycles with history, events and 7000 momentary measurements. With the Access Service Tool, you can also program all Access charger and BMU parameters wirelessly from your PC.
For more information please click here.
The Access Data Collection Unit (DCU) is an accessory to the Access battery charging system that significantly simplifies data collection.
For more information please click here.
PROPERTIES |
|
IP ENCLOSURE | IP54 |
CERTIFICATE | |
REPORTING | IP54 |
APPLICATION | Standard |